Installation Guide
Table Of Contents
7 
an extra component such as a combiner box or an MC4 adaptor for parallel 
strings. Renogy recommends that only sunlight resistant cables be used 
with the minimum wire size being 4mm
2
 in diameter. 
Wiring 
Type 
Ratings 
PV Wire 
PV1-F1x4.0mm
2
Rated Voltage: 1800VDC 
-40ׄ°C Up to 120°C 
MC4 Connectors 
LJQ-1 
Rated Voltage:1800VDC 
Rated Current: 16A 
-40°C Up to 120°C 
Junction Box 
PV-JM801 
Rated Voltage: 1000VDC 
Up to 15A 
  MC4 cables are intended for use on the output wiring of a module or 
panel and comply with the Standard for Connectors for use in 
Photovoltaic Systems, UL 6703, see module literature for appropriate 
mating connectors. 
  Keep connectors dry and clean and ensure that caps are tightly 
sealed before connecting modules 
  Faulty connections can result in electrical shock so make sure to 
fasten all connections securely. 
  Renogy modules can be installed in landscape or portrait orientation. 
Make sure that the proper distance between the panels and the 
surface to allow for air circulation. 
Portrait Orientation    Landscape Orientation 
  Series Connections are just plug and play with the male and female 
MC4 connectors 
  Parallel connections will utilize MC4 branch connectors for 
centralizing all positive and all negative connections. 
  Appropriate MC4 connectors will have a manufacturer name of the 
following: 
Model 
Renogy 
Forward Electronics 
Jiangsu Forward Electronic Technology Co., Ltd 
No. 291 East Street, Zhulin Town, Jintan City, Jiangsu 213241 China
  Compatible manufacturers to Forward Electronics include Multi-
Contact exclusively,  
o  Female Type Multi-Contact KBT4/6I-UR (A: 4 - 6 mm², D: 
5. 5 - 9 mm) (1302020) 
o  Male Type Multi-Contact KST4/6II-UR (A: 4 - 6 mm², D: 5. 
5 - 9 mm) 
  Marking or unique physical features for the connectors will include 
the physical company name, a do not disconnect symbol, a TUV 
certification symbol on the actual connector, and a polarity band 
whether it be red or black, 
5.2 Bypass Diodes 
The junction boxes used with the Renogy modules contain bypass 
diodes that are wired in parallel with the PV string cells. In the event the 
modules experience partial shading, the diodes are activated to bypass 
the current generated by the non-shaded cells, therefore limiting module 
heating and performance losses. However, they do not protect the panel 
from over-current. Over-current protections devices must be used when 
connecting more than 2 modules in series. 
If the bypass diodes are suspected of failure, installers or maintenance 
personnel should contact the company (Renogy). 
Model 
Rating 
SPA2040 
Tj Max = 200°C, if 20A 
  In systems with more than two modules in series, high reverse 
current can flow through cells that are shaded partially or outright 