ANL Fuse RENOGY 20A | 30A | 40A | 60A | 100A ANL Fuse 0 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 1.
General Information Key Features Gold/Nickel plated terminal contact for corrosion resistance Ignition protected Visible through clear window to easily identify open status For use with RENOGY ANL Fuse Block RoHS compliant Dimension 1 2 3 4 5 Dimensions in inches.
Technical Specifications Electrical Parameters Product Current Rating Voltage Rating Interrupt Capacity ANL-FUSE20 20A 72V 180A @48V ANL-FUSE30 30A 72V 200A @48V ANL-FUSE40 40A 72V 240A @48V ANL-FUSE60 60A 72V 360A @48V ANL-FUSE100 100A 72V 500A @48V Mechanical Parameters 3.15 x 0.89 x 0.35 inches 80.0 x 22.5 x 8.7 mm Dimension Weight 0.07 lbs / 31.75 g Standard: DIN43560/1 Functional Characteristics A fuse does not blow when the current reaches its rated current.
Time in Seconds Time-current curves – average melt: Current in Amps Renogy reserves the right to change the contents of this manual without notice.