Instruction Manual

Instruction Manual Dual AutoGate Connect / 2022 Version 3 (GSD-100763)
Page 13
Advanced Settings
Depending on customer or country requirements it may be necessary to turn on/off or
reduce the intensity of the external LED to avoid unwanted attention or to adjust the
number of days that the gate remains open before closing again.
Adjusting the Sensing Mode
Selection of “Rat and Mice” mode Selection of “Rat only” mode
The sensing mode can be set to “Rats only” or “Rats and Mice”:
1. While there is nothing on the digit display press and hold the button
2. Counter begins to count upwards from zero to five followed but ‘A
3. Wait for the display to show the setting next to the ‘A
4. Press the button to select the sensing mode required from the symbols above
5. Wait for the display to go off for the setting to be stored
Adjusting the Gate open time
Once the door has opened and the bait exposed, the time to which the door is closed can be
modified from the default setting of 5 days. This can be set by following these steps:
1. While there is nothing on the digit display press and hold the button
2. Counter begins to count upwards from zero to five followed but ‘A
3. Press the button again to display ‘b’
4. Wait for the display to show the value
5. Push the button to select the number of days between ‘0 – 30’ (Note: 0 means that the
gate will stay open and 1 to 30 is the number of days that it will stay open.) Pressing the
button again once it reaches 30 will start again at 0.
6. Release the button and wait 5 seconds for the setting to be stored.