User's Manual

DCN: 141-02071-01 Page 8
Z-Wave® Installation
The TBZ48 is based on the Slave Library in the Z-Wave Ecosystem.
Z-Wave controllers from various manufacturers support the Z-Wave process of adding or
removing a device from a network. The TBZ48 is a Z-Wave Slave and a Z-Wave controller
is required as the primary controller to setup and maintain the network.
The following procedure will allow the TBZ48 to be included or removed from a Z-Wave
network.
NOTE: If the TBZ48 is installed on a network while running on Batteries, it will be
installed as a FLiRs Z-Wave type of device. If the TBZ48 is installed on a network
while powered by the 24VAC, it will be installed as an always listening device and
can act as a router in the Z-Wave ecosystem.
Once installed, do not change how the thermostat is powered.
Inclusion: Including the TBZ48 into an Existing Network
:
1. Set your primary controller to Include mode, to add the TBZ48 as a node on
your network (see your controller’s user manual for detailed instructions).
2. Press the FAN button and hold until the screen changes to the SETUP
screen.
3. Press the UP button until the ZWAVE is shown on the status line, press
Select.
4. INSTALL should be shown on the status line, press Select. The status line
will show the progress as the TBZ48 has been enrolled into a network. Wait
until SUCCESS or FAILED is shown on the status line.
5. Press Done to exit the ZWAVE screen.
6. Press Done again to exit the SETUP screen. The Radio Icon should be
shown indicating the TBZ48 is enrolled into a network.
Your controller will indicate the TBZ48 was successfully added to its network (see
your controller’s user manual for details). Also you can check if the TBZ48 was
successfully added to the network by checking the ZHID (Home ID) and ZNID (Node
ID) located in the INFO screen. Inclusion and exclusion are always done at normal
transmit power mode.
If your controller supports NWI, then you can optionally set the primary to NWI include
mode. Please note that NWI inclusion mode does not end when you have included a
new node. This allows multiple nodes to be included without having to physically go
back to the controller to initiate the next inclusion. Therefore you must manually
terminate NWI inclusion mode at the controller when you have finished including any
new nodes to the network. Since intermediate included nodes will assist the inclusion
process by routing messages, we recommend that nodes close to the primary
controller be installed first, proceeding out in consecutive rings from the controller.
Note: Before adding the TBZ48 to a Z-Wave Network, check that it does not already
belong to one by viewing the Home and Zone ID’s located in the INFO screen. An
un-configured TBZ48 should show a Node ID of 0 and a random Home ID. Consult