Brochure

3
THE UNIVERSAL CHOICE
Resideo offers a complete range of relays, contactors and transformers for all
your residential and commercial HVAC applications. For reliability, safety and
easy installation, Resideo is the only brand you need.
R24 SERIES ELECTRIC HEAT SEQUENCERS
TRANSFORMERS
The positive temperature coefcient (PTC) heater element provides voltage
compression over a wide voltage range without danger of over-heating at high voltage.
It is self-current limiting, and assures device actuation under low-voltage conditions.
The PTC has the unique feature of always stabilizing at a specic temperature,
regardless of ambient temperature or voltage. This will allow the use of a common
device over a wide voltage range.
Resideo offers NEMA — National Electrical Manufacturers Association — standard
DC20-1992 and general purpose transformers. These transformers are available with
single or multiple input voltages and with foot, conduit and plate mounting options.
Transformers with circuit breakers that can be manu-ally reset by pressing a button
are also available. Resideo also designs transformers for specic environmental
requirements and with specialized termination options.
NEMA-compliant transformers prevent overcooling, brownout, and burnout.
Electric Heat Sequencers
TIMINGS — ON TIMINGS — OFF
Product # Switches Timings M1-M2 M3-M4 M5-M6 M7-M8 M9-M10 M1-M2 M3-M4 M5-M6 M7-M8 M9-M10
R24AA1008 1 1 1-20 40-110
R24AA3004 1 1 30-90 1-30
R24BA1006 2 1 1-20 1-20 40-110 40-110
R24BA3002 2 1 30-90 30-90 1-30 1-30
R24CB4007 3 2 1-110 1-110 1-110 1-110 1-110 1-110
R24DB4005 4 2 1-110 1-110 1-110 1-110 1-110 1-110 1-110 1-110
R24ED5007 5 4 1-160 1-160 1-160 1-160 1-160 1-160 1-160 1-160 1-160 1-160
R24AA3429
CANADA
1 1 15-35 15-35 25-55
Universal Transformers
Electrical
Ratings (VA)
Electrical Ratings
(Input Voltage)
Product
Number
NEMA
Rated Mounting
Main
Connections
Secondary
Connections Frequency
Dimensions (in.)
H x W x D NOTES
40 VA 208/240 Vac AT72D1733 Yes M L S A 3 7/32 x 2 7/32 x 3 1/16 Only in Canada
50 VA 120/208/240 Vac AT87A1106 Yes M L S A 2 15/16 x 2 7/32 x 2 1/4
Built-in protection; Primary
winding burnout
20 VA 120/208/240 Vac AT120A1004 No M L S B 2 7/8 x 1 7/8 x 2 15/16 Metal end bells
40 VA 120/208/240 Vac AT140A1018 No M L S B 3 3/16 x 2 3/8 x 3 1/8 Metal end bells
75 VA 120/208/240 Vac AT175A1008 No M L S B 3 3/16 x 2 3/8 x 3 5/8 Metal end bells
Transformers
Electrical
Ratings (VA)
Electrical Ratings
(Input Voltage)
Product
Number
NEMA
Rated Mounting
Main
Connections
Secondary
Connections Frequency
Dimensions (in.)
H x W x D NOTES
19 VA 120 Vac AT20A1123
Yes
F L L
A
2 x 2 1/4 x 1 7/8
40 VA
120 Vac
AT72D1006 P S
3 7/32 x 2 7/32 x (1 1/16
into x 2 in. above plate)
AT72D1089 F S 3 7/32 x 2 7/32 x 3 1/16
AT72D1188 P L 3 7/32 x 2 7/32 x 2 15/16
AT72D1683 M S
3 7/32 x 2 7/32 x 3 1/16AT72D1956 M L Only in Canada
208/240 Vac AT72D1691 M S
48 VA
277 Vac AT87A1189 F L
2 15/16 x 2 7/32 x 2 1/4
Energy limiting overload
protection
480 Vac AT87A1155 F L
Energy limiting overload
protection
20 VA 120 Vac AT120B1028
No
F L
B
1 11/16 x 3 3/16 x 1 3/4 Metal end bells
40 VA
120 Vac
AT140A1000 M S 3 3/16 x 2 3/8 x 3 1/8 Metal end bells
AT140B1206 F L 1 11/16 x 3 1/2 x 1 3/4 Plastic end caps
120/208/240 Vac AT140B1214 F L 1 11/16 x 3 1/2 x 1 3/4 Plastic end caps
50 VA
120/208/240 Vac
AT150A1007 M
L
S 1 11/16 x 3 3/16 x 1 3/4 Metal end bells
AT150F1022 M L 3 3/16 x 2 3/16 x 3 5/8
Button for resetting circuit
breaker & metal end bells
208/277/480 Vac AT150F1030 M L 3 3/16 x 2 3/16 x 3 5/8
Button for resetting circuit
breaker & metal end bells
277 Vac AT150B1252 F L, Q L, Q A 1 11/16 x 3 1/2 x 1 3/4 Plastic end caps
75 VA
120/208/240 Vac AT175F1023 M
L
L
B
3 3/16 x 2 3/16 x 3 15/16
Button for resetting circuit
breaker & metal end bells
208/277/480 Vac AT175F1031 M L 3 3/16 x 2 3/16 x 3 15/16
Button for resetting circuit
breaker & metal end bells
120 Vac AT88A1005 F L
A 2 15/16 x 2 3/16 x 3 5/16
Internally fused secondary for
overload protection
208/240 Vac AT88A1021 F L
480 Vac AT88A1047 F L
Temperature: -50˚ F to 165˚ F
Table Notes:
M1-M2 and M3-M4 are always rst switches to turn ON and last to turn OFF.
All other switches are random ON and random OFF.
R24ED5007 Switch contacts designated F1-F2 instead of M1-M2.
R24BB3428 is Double Pole Double Throw model.
R24AA2006 is a Single Pole Double Throw model for Heat Pump Applications.
These contacts switch simultaneously.
ON Time: Elapsed time (min. to max.) to make contact after heater is energized.
OFF Time: Elapsed time (min. to max.) to break contact after heater is de energized.
Terminations: Solder or screw type 1/4” quick connect
Ratings: Estimate — 25 A resistive and 14 A inductive at 120 Vac
SPST: Single Pole Single Throw
DPST: Double Pole Single Throw
SPDT: Single Pole Double Throw
DPDT: Double Pole Double Throw
Agency: UL/CSA
Frequency: A — 60 Hz/50 Hz; B — 60 Hz;
Mounting; C — Conduit ; F — Foot; P — Plate; M — Foot, Conduit, Plate (F models do not come with plate options)
Connections: L — Leadwires (9 in. to 13 in.); Q — Quick Connects; S — Screw Terminals
Approval: UL, CSA
Heat Pump — Air Handler Model
Model # Switches Timings Heat Cool
R24AA2006 1 1 1-60 75-95