Users Manual

RTF0B4T1AL59UB
@2019Resideotechnologylnc..8
58
GND Ground
59
GND Ground
2 Electrical Performance
Table 2-1:Absolute Maximum Ratings
Stresses above those listed under “Absolute Maximum Ratings’ may cause permanent damage to the device. This is a
stress rating only and functional operation of the device at those or any other conditions above those indicated in the
operation listings of this specification is not implied. Exposure to maximum rating conditions for extended periods may
affect device reliability.
Parameter
Min.
Typ.
Max.
Units
Input Voltage (Vbat) 0
3.6 V
Operating Temperature -40
85 ºC
Table 2-2:DC Characteristic
Parameter
Min.
Typ.
Max.
Units
I/O current sink/source capability
8
mA
supply voltage 2
3.6 V
Table 2-3:ADC
Parameter
Description
Min.
Typ.
Max.
Units
Resolution 200kHz Clock
12 Bits
Table 2-4:Current Consumption
Power Consumption - Power Modes
All electrical parameters in all tables are specified under the following conditions, unless stated otherwise:Typical values
are based on Tc = 25°C,V
DD
= 3.63V.