FAN AND LIMIT CONTROLS
Resideo fan and limits combines high temperature limit with circulating blower control. As an industry
standard for many years, these controls have a large and varied installed base. You’ll nd Resideo fan and
limits on a wide range of furnace equipment. Our universal family increases service eciency and reduces
truck and warehouse inventory.
Key features for the family of universal fan and limits:
Family members cover the full range of insertion — 5”, 8”, 11-1/2”
Adjustment tool and cross reference allow for eld adjustment to factory settings
Universal kit accessories reduce inventory
L4064
HIGH LIMIT AND FAN CONTROLLER
Used in all types of forced-air heating systems
Three wiring terminal options available for easy installation
Available in a variety of fan and high-limit setting ranges
Controls adapt to many competitive mounting holesin
replacement applications
Push-in receptacles for stripped wire
L4064 models for timed fan on
Special high temperature limit models available
Suitable for line voltage, low voltage or millivoltage
control applications
Fan and Limits Selection Guide
Model OS# Region
Element
Insertion
Length
(in.) Replaces
High
Limit
Stop
Fan-
On
Stop
Fan-
Off
Stop
Manual
Fan
Button
Manual
Reset Switching Action
L4064
L4064B2228
US/
Canada
5
L4064A1339, L4064A1503, L4064A1586, L4064A2402,
L4064A2659, L4064A2980, L4064B1469, L4064B1683,
L4064B2228, L4064B2640, L4064B2657, L4064B2681,
L4064B2889, L4064B2897, L4064B2947, L4064B3010,
L4064B3143, L4064B3143, L4064B3374, L4064B3432,
L4064B3440, L4064B3473, L4064B3598, L4064E1983,
L4064E2437, L4064E2544, L4064L1046
200°F
97°C"
125°F
52°C
100°F
38°C
Yes No
Fan: SPST–N.O.
(make on rise),
Limit: SPST– N.C.
(break on rise)
L4064R1159
US/
Canada
5
L4064E1835, L4064E255, L4064L1145, L4064R1043,
L4064R1050, L4064R1159
250°F
121°C
125°F
52°C
100°F
38°C
Yes No
Fan: SPST–N.O.
(make on rise),
Limit: SPST –N.C.
(break on rise)
L44064B2236
US/
Canada
8
L4064A1347, L4064A1511, L4064A1719, L4064A1735,
L4064A2030, L4064A2279, L4064A2998, L4064B1618,
L4064B2236, L4064B2608, L4064B2772, L4064B2822,
L4064B2905, L4064B2905, L4064B2962, L4064B3051,
L4064B3085, L4064B3325, L4064B3333, L4064B3341,
L4064B3366, L4064B3457, L4064B3499, L4064B3572,
L4064E1777, L4064E2163, L4064E2171, L4064E2452,
L4064E2502, L4064E2684, L4064F1023, L4064F1031,
L4064F1080, L4064F1098, L4064L1004, L4064A2774
200°F
97°C"
125°F
52°C
100°F
38°C
Yes No
Fan: SPST–N.O.
(make on rise),
Limit: SPST– N.C.
(break on rise)
L4064R1142
US/
Canada
8
L4064A2469, L4064B1691, L4064B2616, L4064B2806,
L4064B2814, L4064B2830, L4064B3390, L4064B3481,
L4064B3507, L4064R1019, L4064R1118, L4064R1126,
L4064R1142
250°F
121°C
125°F
52°C
100°F
38°C
Yes No
Fan: SPST–N.O.
(make on rise),
Limit: SPST –N.C.
(break on rise)
L4064B2210
US/
Canada
11.5
L4064A1321, L4064A1453, L4064A2758, L4064A3012,
L4064A3020, L4064A3038, L4064A3046, L4064B1451,
L4064B1592, L4064B1717, L4064B1725, L4064B1931,
L4064B2210, L4064B2723, L4064B2749, L4064B2848,
L4064B2954, L4064B3036, L4064B3044, L4064B3077,
L4064B3184 L4064B3465, L4064B3580, L4064E2056,
L4064E2114, L4064E2130, L4064E2155
200°F
97°C"
125°F
52°C
100°F
38°C
Yes No
Fan: SPST–N.O.
(make on rise),
Limit: SPST– N.C.
(break on rise)
L4064R1134
US/
Canada
11.5
L4064A2972, L4064B2756, L4064J1008, L4064K1006,
L4064L1129 L4064N1074, L4064R1027, L4064R1035,
L4064R1068, L4064R1134, L4064R1167
250°F
121°C
125°F
52°C
100°F
38°C
Yes No
Fan: SPST–N.O.
(make on rise),
Limit: SPST –N.C.
(break on rise)
*
Fan On and Fan Off may need to be adjusted.