User's Manual

RE108_Hardwire_to_GE-Compat_Translator.doc
Page 2 of 3 21-Sep-09
www.ResolutionProducts.com
Specifications
GE Device Type: 10 (all 8 zone ID’s and device ID)
Zone sensing duration: State sensed if held more than 600ms.
End-of-line Resistors: 4.7k-ohm, 5%.
Max wire run: 1000 feet
Backup batteries: Two AAA Alkaline.
External supply: 7-14V AC or DC, at least 50mA.
Current draw with supply: 4mA, normal operation.
PIR usage: Supply must be DC only. PIR may need tighter
voltage tolerance. Add PIR and device
current requirements together to get total
current need.
AC Fail Conditions: AC gone for 15 minutes. Restores on AC
restore.
Device Low Battery Conditions: Low battery for 1 minute. Restores on
device tamper, AC restore.
Back-up Battery Life on AC Fail: 2 years, all zones terminated in 4.7K;
longer if unused/open.
Housing dimensions: 4x6x1 inches
Specifications subject to change without notice.
Internal Picture
Terminals for Zones 3
-
8
Terminals for Zones 3
-
8
Power Terminals
Tamper / Enroll Switch