Installation Guide

The RE229 Glassbreak is a security sensor that
detects the sound of breaking glass and sends alarm
signals to the security panel.
Features
Variable detection range of up to 20 feet
Low battery and tamper indication
VHB™ tape included for easy installation
Enroll by placing the panel into wireless enrollment
mode and removing the battery tab. Ensure Loop 1
is selected.
Select sensitivity by adjusting the dipswitch. See
table below for sensitivity settings.
Select a mounting location at a height of at least
6.5 feet (2m) and no more than 20 feet (6m) from the
window you wish to protect. Ensure the sensor has
visual line-of-sight to all windows being protected.
Use a glassbreak tester to conrm operation before
permanently mounting using the mounting screws or
VHB tape.
Test the glassbreak to verify operation after
enrollment and installation. Note, any glassbreak
tester can be used.
1. The sensor is in test mode for 5 minutes after
powered. When test mode is active, the LED will
ash once per second.
2. Activate the glassbreak tester near the window
you wish to protect.
3. If an alarm is detected, the LED will ash rapidly
for 2 seconds and an alarm signal will be sent
to the panel. If the sensor does not trip, check
the sensitivity setting or relocate the sensor and
retest.
Use the panel installation guide to verify proper system setup.
RE229 Glassbreak
Honeywell
®
Compatible
I
N
S
T
A
L
L
G
U
I
D
E
SENSITIVITY DETECTION
RANGE
SWITCH 1 SWITCH 2
MAX 20FT OFF OFF
MEDIUM 13FT OFF ON
LOW 8FT ON OFF
LOWEST 5FT ON ON
Resolution Compatibles
Mounting Holes
Sensitivity Switches
ON