User's Manual

RE301_DSC-Compat_DWS_Instructions.doc
Page 1 of 3 7/22/2011
www.ResolutionProducts.com
Wireless
Security
Solutions
RE301 DSC-Compatible Standard Door / Window
Features
For sensing things that open or separate.
3 total zones. Each with separate ESNs.
o Main reed switch + magnet
o 2 supplemental hardwire zones
Outer terminal.
Inner terminal.
Cover tamper.
Strong, reliable RF signal.
10-15 year battery life on CR123A battery.
Low Battery indication.
Key Instructions
Battery “+” faces towards spring.
DWS has 3 zones with 3 ESNs. But when it comes from the factory, only
the magnetic reed switch reports to the panel. The other two external
contact zones must be “activated” in order to report.
External contact zones are: normally closed – alarm on open.
No end-of-line resistors on external contact zones.
Activating Zones – ACTIVATE ONLY THE ZONES YOU NEED:
Reed switch Zone 0:
ESN ends in “0” and is labeled on the DWS battery bucket.
Comes from factory already activated.
External Contact Zone 1:
Outer terminal + Center Terminal
ESN is same as Reed switch, except it ends in “1”
Activate by shorting Zone 1 while installing battery.
External Contact Zone 2:
Inner terminal + Center Terminal
ESN is same as Reed switch, except it ends in “2”
Activate by shorting Zone 2 while installing battery.
Enrolling Zones in DSC Panel:
Put panel in Wireless Enrollment Mode.
Set all active zones on the DWS to NON-Alarm state.
Open (alarm) only the zone on the DWS that you want to enroll.
Confirm ESN, Enter Zone # and Zone Type on DSC Panel.
May also be enrolled via entering ESN.
RE301_DSC-Compat_DWS_Instructions.doc
Page 2 of 3 7/22/2011
www.ResolutionProducts.com
Operation
Magnetic reed switch (ESN “0”):
Alarm, when magnet is pulled away from reed switch.
External Contact zones (Outer=ESN “1”, Inner=ESN “2”)
Each zone functions ONLY if Activated AND Enrolled in panel.
Alarm: when contact opens.
Zones function independently and send separate ESN signals.
Tamper reports on each and every active zone, when cover is opened.
Supervisory signals sent for each and every active zone, every hour.
Specifications
Magnet trip distance: 1 inch nominal
Mounting hardware: # 4 or #6 screws
Replacement Battery: CR123A 1550mAH
Temperature Range: 0F to 120F
Housing dimensions: 3.3x1.4x1.1 inches
Specifications subject to change without notice.
Internal Picture
ESN ending in “1”
Outer Terminal Zone
Activated by loop being
shorted during power-up
Center Common Terminal
ESN ending in “2”
Inner Terminal Zone
Activated by loop being
shorted during power-up
ESN ending in “0”
Magnetic Reed Switch
Comes from factory active
Tamper