User's Manual
RE301_DSC-Compat_DWS_Instructions.doc
Page 1 of 3 7/22/2011
www.ResolutionProducts.com
Wireless
Security
Solutions
RE301 DSC-Compatible Standard Door / Window
Features
• For sensing things that open or separate.
• 3 total zones. Each with separate ESNs.
o Main reed switch + magnet
o 2 supplemental hardwire zones
Outer terminal.
Inner terminal.
• Cover tamper.
• Strong, reliable RF signal.
• 10-15 year battery life on CR123A battery.
• Low Battery indication.
Key Instructions
• Battery “+” faces towards spring.
• DWS has 3 zones with 3 ESNs. But when it comes from the factory, only
the magnetic reed switch reports to the panel. The other two external
contact zones must be “activated” in order to report.
• External contact zones are: normally closed – alarm on open.
• No end-of-line resistors on external contact zones.
• Activating Zones – ACTIVATE ONLY THE ZONES YOU NEED:
Reed switch Zone 0:
ESN ends in “0” and is labeled on the DWS battery bucket.
Comes from factory already activated.
External Contact Zone 1:
Outer terminal + Center Terminal
ESN is same as Reed switch, except it ends in “1”
Activate by shorting Zone 1 while installing battery.
External Contact Zone 2:
Inner terminal + Center Terminal
ESN is same as Reed switch, except it ends in “2”
Activate by shorting Zone 2 while installing battery.
• Enrolling Zones in DSC Panel:
Put panel in Wireless Enrollment Mode.
Set all active zones on the DWS to NON-Alarm state.
Open (alarm) only the zone on the DWS that you want to enroll.
Confirm ESN, Enter Zone # and Zone Type on DSC Panel.
May also be enrolled via entering ESN.
RE301_DSC-Compat_DWS_Instructions.doc
Page 2 of 3 7/22/2011
www.ResolutionProducts.com
Operation
• Magnetic reed switch (ESN “0”):
Alarm, when magnet is pulled away from reed switch.
• External Contact zones (Outer=ESN “1”, Inner=ESN “2”)
Each zone functions ONLY if Activated AND Enrolled in panel.
Alarm: when contact opens.
Zones function independently and send separate ESN signals.
• Tamper reports on each and every active zone, when cover is opened.
• Supervisory signals sent for each and every active zone, every hour.
Specifications
Magnet trip distance: 1 inch nominal
Mounting hardware: # 4 or #6 screws
Replacement Battery: CR123A 1550mAH
Temperature Range: 0F to 120F
Housing dimensions: 3.3x1.4x1.1 inches
Specifications subject to change without notice.
Internal Picture
ESN ending in “1”
Outer Terminal Zone
Activated by loop being
shorted during power-up
Center Common Terminal
ESN ending in “2”
Inner Terminal Zone
Activated by loop being
shorted during power-up
ESN ending in “0”
Magnetic Reed Switch
Comes from factory active
Tamper