Installation Guide

The RE629 Glassbreak is a security sensor that detects
the sound of breaking glass and sends alarm signals to
the security panel.
Features
Variable detection range of up to 20 feet
Low battery and tamper indication
VHB™ tape included for easy installation
Enroll by placing the panel into wireless enrollment mode
and sending an enrollment signal. Alternatively, the
sensor can be enrolled by scanning its bar code using
the Connect+ Installer App or by entering its 8-character
serial number in the AlulaConnect portal.
Select sensitivity by adjusting the dipswitch. See table
below for sensitivity settings.
Select a mounting location at a height of at least
6.5 feet (2m) and no more than 20 feet (6m) from the
window you wish to protect. Ensure the sensor has
visual line-of-sight to all windows being protected.
Use a glassbreak tester to conrm operation before
permanently mounting using the mounting screws or
VHB tape.
Test the glassbreak to verify operation after enrollment
and installation. Note, any glassbreak tester can be
used.
1. The sensor is in test mode for 5 minutes after
powered. When test mode is active, the LED will
ash once per second.
2. Activate the glassbreak tester near the window you
wish to protect.
3. If an alarm is detected, the LED will ash rapidly
for 2 seconds and an alarm signal will be sent to
the panel. If the sensor does not trip, check the
sensitivity setting or relocate the sensor and retest.
Use the panel installation guide to verify proper system setup.
RE629 Glassbreak
Connect+
Encrypted
I
N
S
T
A
L
L
G
U
I
D
E
Sending an Enrollment Signal
Remove the battery tab to power the device or
tamper the device by opening the enclosure.
SENSITIVITY DETECTION
RANGE
SWITCH 1 SWITCH 2
MAX 20FT OFF OFF
MEDIUM 13FT OFF ON
LOW 8FT ON OFF
LOWEST 5FT ON ON
Mounting Holes
Sensitivity Switches
ON