Installation guide
4 Advisor Master Programming Guide
How to program the options
For information on which keys to use while programming, please refer to these
pages.
Accessing the installer programming menu
The ATS system is programmed from the Installer programming menu. Before
accessing the programming menu the system must be disarmed.
Note: Depending on system options, an additional authorization can be required.
For more details, see:
• “Installer dual code” en page 84.
• “PIN of the day option” on page 89.
See also Advisor Master Manager Manual.
How to access the installer programming menu:
1. Press Menu and enter 1278 (master engineer code), and then press Enter.
Note: In Grade 3 compliant system the default master engineer code is
001278. In Grade 2 compliant system the default master engineer code is
01278.
The following display appears:
0-Exit, ENTER-Down, *-Up
0-Exit, Menu:
Note: There is a prompt to apply EN 50131 default settings during the first
startup. See “First startup” on page 6 for more details.
2. Press 19 and Enter.
The following display appears:
Simple/Advanced Menu
*-Advanced
3. Press Enter to access the Simple Menu (or press * to access the Advanced
Menu).
The following display appears:
Installer Programming
0-Exit, Menu:
You can now select the menu option you want to program. See “Programming
map” on page 218 for the programming map that lists all the menu options
available in the Programming menu.
Note: The chapter and section numbering in the manual follow the menu option
numbering. For example, Chapter 1 describes menu 1 “Zone database”.