Installation guide

96 Advisor Master Programming Guide
200 baud reverse area OP/CL
No 200 Baud Reverse Area Open/Close
*-Change 0-Skip
If set to No, disarm events are reported as type A and arm events are reported
as type R (Default)
If set to Yes, disarm events are reported as type R and arm events are reported
as type A
X25 TEI value
X25 TEI Value
Value:
The X25 TEI value for the ISDN-D channel connection. The range is from 1
to 63.
Audio listen in time
Audio Listen In Time - 180
Time:
The total time in seconds that the panel will transmit audio to the monitoring
station. Note that the actual time of the audio transmission can be manually
stopped or extended by the receiver. Range is 10 to 255 s.
Audio listen in frame
Audio Listen In Frame Time - 30
Time:
The time in seconds for each audio frame. During transmission the audio is
broken into frames or blocks. Range is 10 to “Audio listen in timeabove.
Report mains fault
YES-Report Mains fault
*-Change 0-Skip
Yes: Mains faults are reported.
No: Mains faults are not reported.
Note: Setting is ignored if “Enable buzzer on mains/line faulton page 84 is set
to Yes.
Report line fault
YES-Report Line fault?
*-Change 0-Skip
Yes: Line faults are reported.
No: Line faults are not reported.