14-Defaults
Sometimes it is necessary to bring the control panel back to factory defaults. For
example when a system is going to be programmed for the first time or when
programming a system that has been de-powered for an extended period (more
then 2 weeks).
Select default option
99-All, 98-STD, 97-Output/Groups, 95
Software IUM
Option:
Select the programmed options to bring back to factory default.
99-All
Resets all the system records to the factory default. All
programming is erased.
98-STD (standard)
Resets some of the programming menus. The following menus
are defaulted:
• Area database
• Alarm groups (11-29)
• Timers
• System options
• Auto reset
• Timezones
• Alarm group restrictions
• Auto Arm/disarm
• Areas assigned to vaults
• Area linking
• Timezone to follow output
97-Outputs and groups
Resets the event to output records, the door and floor groups.
95-Software IUM
This option upgrades the panel to Software IUM. By using this
option the different memories will be converted as listed in
Table 10 below.
93-Grade 3
Set default values for EN 50131 Grade 3 compliance. This is also
a prerequisite for PD 6662-2010 compliance.
See “Options required by EN 50131 compliance” on page 198 for
more information.
Note: There is a prompt to apply these settings after the first
installer login. See “First startup” on page 6 for more details.
Table 10: Software IUM conversion