Installation guide

116 Advisor Master Programming Guide
Alarm group restriction 7
Emergency:
Special function for Security
Guards on a guard tour who
need to check in at certain
intervals.
As alarm group restriction 1 to 6, except that when the timer
expires and the areas re-arm, an “Emergency” message is
reported to the central station.
Alarm group restriction 8 -
Counter:
Special Function: User count for
each area
When the users enter their code to re-arm, the user count for
each area decreases by one.
The display always shows the user count.
The area can be armed by the users by re-entering their code
to arm, provided the user count for each of the areas to be
armed, is down to 1 before the code is entered. I.e. the next
code reduces the count to 0 and arm the area(s).
Timers do not operate for alarm group restriction 8.
Can count a maximum of 255 users per area.
2. Arm/reset of areas
Only arm/reset functions apply to areas assigned to an alarm group and
programmed as Areas to arm/reseton page 117 in Alarm group restriction
menu. When a user enters a code, it arms the programmed areas, regardless of
any timers running (but cannot disarm), or it resets alarms in the programmed
areas.
3. Timed disarm and arm/reset
Both timed disarm and arm/reset functions apply to areas assigned to an alarm
group and programmed both as Timed disarm areason page 117 and Areas to
arm/reseton page 117.
When a user enters a code, all the timed disarm functions apply except when re-
entering a code the arm/reset function applies and the system is armed
regardless of any timers running.
4. No alarm group restriction assigned
Areas assigned to an alarm group, but not included in the alarm group restriction
menu, have standard alarm system control functions as specified in the alarm
group. E.g. code, On/Off to arm/disarm etc.
Notes
Program the length of time that the timer runs for in 6-Timers(page 62), or
2-Area database (page 28). If the timer is set to zero, the alarm group
restriction does not time out. The alarm group restriction functions in exactly
the same way except a timer does not run and therefore does not arm areas
on expiry.
Program the warning time that appears on the display and sounds an audible
alert in 6-Timers (page 62).
Assign the alarm group restriction to alarm groups in the menu 5-Alarm
groups (page 50).