Installation guide
118 Advisor Master Programming Guide
1st alternate timed disarm area
9,10,
2, Timed Area:
As explained in “5-Alarm groups” on page 50, it is possible to have alternate
alarm groups. The alternate alarm group is used when the original alarm group is
not available due to an invalid timezone.
When an alternate alarm group is active and the alternate alarm group has an
alarm group restriction, the alternate alarm group restriction is used.
For example
Three alarm groups have been set up:
Option
ALARM GROUP
32
33
34
Area
1, 2
1, 2
1
Alarm group restriction
4
4
4
Timezone
1
2
0
Alternate alarm group
33
34
1 ( = none)
Alarm group restriction 4 is programmed:
Option
Standard
1st alternate
2nd alternate
Timed disarm Area
-
2
1
Arm/Reset Area
2
-
-
Alarm group 31 is assigned to user 1. Alarm group 32 is assigned to user 2.
Operation:
• Timezone 1 is valid. User 1 will have alarm group 31 with alarm group
restriction 4, standard. Has full control over area 1 and can arm and reset
area 2. Timezone 1 does not effect alarm group 32 (= user 2).
• Timezone 1 is invalid but timezone 2 is valid. User 1 will have the 1st
alternate alarm group (32) and alarm group restriction 4, also 1st alternate.
Has full control over area 1. Has timed disarm for area 2.
User 2 will have alarm group 32 and alarm group restriction 4, standard. Has
full control over area 1, and can arm and reset area 2.
• Timezone 1 and 2 are invalid. User 1 will have the 2nd alternate alarm group
(33) and alarm group restriction 4, also 2nd alternate. Has timed disarm for
area 1, and no control over area 2.
User 2 will have the 1st alternate alarm group (33) and alarm group restriction
4, also 1st alternate. Has full control over area 1, and no control over area 2.