Installation guide
Advisor Master Programming Guide 123
17-Auto arm/disarm
To automatically arm and/or disarm areas, timezones are used. Areas being
armed or disarmed automatically do not require any user action.
Note: If the “Prevent arming on faults” option described on page 88 is set to Yes,
particular faults may prevent auto arming. To avoid this, make sure that the
selected alarm group in “Alarm group to auto arm/disarm” below allows forced
arming. See also “Using alarm group restrictions in conjunction with auto
arm/disarm” on page 124.
Auto arm/disarm program
Auto Arm/Disarm
Program No:
Enter the program number (1 to16 available).
Configuring auto arm/disarm
Timezone to arm/disarm
Pgm: 1 TimeZone 2
Timezone No:
Enter the timezone to be used for automatic arming/disarming. When the
timezone becomes valid (at the start time) the area disarms. When the specific
timezone expires (at the end time) the areas arm.
See also “13-Timezones” on page 111.
Alarm group to auto arm/disarm
Pgm: 1 Alm-Grp: 14-Area One
Alm-Grp:
The alarm group is used to determine which areas are automatically armed or
disarmed, and if the specified areas are to be automatically armed, disarmed or
both.
If an alarm group restriction is linked to the alarm group, the automatic arming
can be postponed by a preset time (alarm group restriction disarmed time, see
“6-Timers” on page 62).
Notes
• The settings in the alarm group determine the exact operation of this function.
The function follows all the guidelines of the alarm group regarding alarm
control. For example, if the alarm group setting for Arm and Reset only is set
to Yes, then the areas assigned will only automatically arm.