Installation guide

124 Advisor Master Programming Guide
If the alarm group setting for disarm only is set to Yes, then the assigned
areas will only automatically disarm. See 5-Alarm groups on page 50 for
further information.
If the alarm group setting for any alarm group restriction is set to Yes, then a
user can extend the time that the area(s) are disarmed for a specified period.
See Using alarm group restrictions in conjunction with auto arm/disarm
below for further information.
Each combination of a timezone and an alarm group is called a program.
There are 16 programs, one for each possible area. A different program must
be completed for each area, or set of areas, where you require different
functions. E.g. disarm at different times.
When programming alarm groups, a timezone can be assigned to the alarm
group to specify when the alarm group is valid. The alarm group assigned to
an arm/disarm timer program does not require a timezone in the alarm group.
If both the alarm group and the auto arm/disarm have a timezone, check that
the timezone in the alarm group does not conflict with the timezone for
automatic arm/disarm.
Using alarm group restrictions in conjunction with auto
arm/disarm
Users can postpone the time that the area(s) will arm by entering their code (or
presenting their card) during the "Warning Time”. Link an alarm group restriction
to the alarm group for the area(s) to postpone by setting Timed disarm areason
page 117.
Program the following items to achieve this function:
An alarm group restriction must be programmed with the areas required to
timed disarm (the area(s) must also be included in any alarm groups that the
alarm group restriction is assigned to - see below).
The same Alarm group restriction (as programmed above) must be set to Yes
in:
- The alarm group used in the arm/disarm timer program.
- The alarm group assigned to the arming station(s) or door reader(s) at which
the user is required to perform the function.
- The alarm group assigned to the user(s) who will perform the function.
The required times must be programmed in 6-Timerson page 62:
- AG restriction 1 disarmed timeon page 62. The time the automatic arming
will be postponed.
- Warning timeon page 63. The time that the warning sounds (on the
keypad buzzer) before the area(s) automatically arm. The code/card must be
presented during the warning period to postpone the automatic arming.