18-Vaults
Vault areas are areas that will automatically arm other areas after a preset time
once they are armed. A user that has the vault areas in his alarm group arms the
vault areas. The time starts only if all vault areas are armed. The user does not
need to have alarm control over the areas that are automatically armed.
2, 3, 4,
Area:
By using a special programming procedure, an alarm group restriction timer
starts when all the vault areas are armed. When the timer expires, a non-vault
area linked to the vault areas will automatically arm.
For example: A building has three office areas (areas 3, 4, and 5), a common
foyer (area 1) and a common canteen (area 2). Assigning the office areas as
vaults allows the foyer and the canteen to be armed at a set time after the last
office is armed.
Other programming to be done:
Areas (3, 4, and 5) must be assigned to vaults on this option.
Set Disable insert of AG restrictionon page 75 to No.
The areas to be timed on (1 and 2) must be linked to the areas designated as
vaults in 19-Area linking on page 127 (areas 1 and 2 linked to areas 3, 4,
and 5).
The linked areas not assigned as vaults (area 1 and 2) must be included in an
alarm group restriction to Timed disarm areason page 117.
The delay time required for the areas to on arms is programmed in 6-Timers
(page 62) as alarm group restriction disarmed time. Use the same alarm
group restriction as above.
The alarm group restriction is then inserted into the necessary alarm groups
(Assigned to users/RASs) to enable the function to be used. The alarm group
must include the areas assigned to the alarm group restriction if the
restrictions are to operate.