Installation guide
Advisor Master Programming Guide 133
Zone holds event flag for 2 seconds
NO-Zone Holds Event Flag for 2 Sec.
*-Change 0-Skip
Delay cancelling of the door event flag. It is used for doors with magnetic locks
and drop bolts.
Yes: In order to allow time for a door to be properly closed, there is a 2-second
delay after the zone switches to normal and before it cancels the door event and
shunt timer.
No: There is no delay.
Press 0 to end programming this shunt timer and to select a new shunt timer.
Entry/exit shunting
NO-Entry/Exit Shunting
*-Change 0-Skip
Allows the shunted zone to be treated as an entry/exit zone.
Yes: A code must be entered to start the shunting or before the shunt timer
expires, otherwise an alarm is generated.
No: The shunted zone is not treated an entry/exit zone.
Press 0 to end programming this shunt timer and to select a new shunt timer.
Note: If this option is set to Yes, the “Door open command starts shunt” on page
131 must be set to No.
Log door open/close
NO-Log Door Open/Close
*-Change 0-Skip
Allow for the zone to be logged on printer as door open/close when it switches
between normal and active.
Yes: Every time the zone changes status, it is logged to the printer.
No: No reporting to the printer.
Press 0 to end programming this shunt timer and to select a new shunt timer.
Note: If “Print zone when active” on page 26 is set to Yes for the zone assigned
to the shunt timer, a door open message is sent twice.