Installation guide
134 Advisor Master Programming Guide
22-Timezone to follow output
Select a timezone to follow an output. When the output is active, the timezone is
valid. Use this option to invalidate alarm groups if certain conditions are not met.
For example:
• Prohibit the use of a keypad, unless a keyswitch on a zone is active.
• Allow an area to be disarmed only if another area is disarmed before.
The timezones that follow outputs are also referred to as soft timezones. Hard
timezones are valid between a start and end-time.
Select timezone
Output To Timezone
Tz (26-41)
Select the timezone to follow the output (timezones 26 to 41 are available).
Assign output to follow
Tz 27 To Follow Output 3
Output No:
Assign the output the timezone has to follow.
Notes
• When programming door groups, timezones 26 to 41 can only be used with
doors 1 to 16.
Doors 17 to 64 are only available on 4-Door DGPs that only recognise
timezones 0 to 24.
Timezones 26 to 41 can never be used in door or floor groups.
• If the output is inverted, timezones 26 to 41 are valid if the output is not active
(the event flag is not triggered).