Installation guide

134 Advisor Master Programming Guide
22-Timezone to follow output
Select a timezone to follow an output. When the output is active, the timezone is
valid. Use this option to invalidate alarm groups if certain conditions are not met.
For example:
Prohibit the use of a keypad, unless a keyswitch on a zone is active.
Allow an area to be disarmed only if another area is disarmed before.
The timezones that follow outputs are also referred to as soft timezones. Hard
timezones are valid between a start and end-time.
Select timezone
Output To Timezone
Tz (26-41)
Select the timezone to follow the output (timezones 26 to 41 are available).
Assign output to follow
Tz 27 To Follow Output 3
Output No:
Assign the output the timezone has to follow.
Notes
When programming door groups, timezones 26 to 41 can only be used with
doors 1 to 16.
Doors 17 to 64 are only available on 4-Door DGPs that only recognise
timezones 0 to 24.
Timezones 26 to 41 can never be used in door or floor groups.
If the output is inverted, timezones 26 to 41 are valid if the output is not active
(the event flag is not triggered).