Installation guide
Advisor Master Programming Guide 139
29-Computer connection
Holds programming concerning connection to a computer running software
package to program or control the ATS system (for example, ATS8100 or
ATS8300).
See also the “Service menu” in Advisor Master Manager Manual.
When connecting the panel directly via the J18 (on-board RS232 port) or
connecting the panel via the ATS1801 computer/printer interface, it is not
necessary to set menus 29.1 to 29.4.
When connecting the panel as a remote connection: via the on-board PSTN
dialler or the ISDN interface (ATS71xx) (300 baud) or via a stand-alone ISDN or
PSTN modem connected to the ATS1801 computer / printer interface
(4800 baud), at least Menu 29.1 needs to be set to ON.
Note: Every Advisor Master control panel has address 1 as the default. When
operating in multi panel configurations with 2 or more panels (only applicable for
Titan Security System Software; not applicable for Alliance), you have to set the
corresponding panel address as a unique value for each panel in Menu
“Computer address” on page 142.
To ensure optimum security, it is advisable to select the following options for
menus 29.1 to 29.4:
• Menu 29.1 — Yes
• Menu 29.2 — No
• Menu 29.3 — No
• Menu 29.4 — No
For EN 50131 and PD 6662:2010 compliance, it may be required to enable the
option authorized computer connection, where a user has to authorize computer
connections. See also “Authorize computer connection” on page 144.
Computer connection settings
Enable remote up/download
Yes–Enable Remote Up/Download
*-Change 0-Skip
Specify if connecting to a remote computer is possible.
Yes: A remote connection (up/download) is possible.
No: Remote Up/Download is not possible.
Press 0 to go directly to Menu 29.8
Notes
• Set this option to Yes to use menus 29.2 to 29.5.
• Before commissioning a system, the Advisor Master control panel must be
provided with a Security Password in Menu 29.12.