Installation guide
Advisor Master Programming Guide 141
Use modem init string
Yes-Use Modem Init. String
Change 0 - Skip
Note: Option 29.1 must be set to Yes to use this option.
Yes: Up/download uses a compatible modem connected to the ATS1801.
No: Up/download uses the built-in modem.
Note: Refer to options (29.1, 29.2, 29.3, 29.4) only for incoming calls or call-
backs. Events sent via modem depend on options 29.6, 29.7 and the computer
phone number.
Enter modem init string
(*)-End Enter 32 char init modem string
If Menu 29.5 is set to Yes, enter the modem initialization string (you can enter up
to 32 characters.) This modem initialization string is sent to a compatible modem
on the ATS1801 (serial printer/computer interface board). The 32 character entry
allows for the following characters: @&/=%+-,;
Press OFF or “*” twice to move onto Menu 29.6.
Report alarms to computer
No–Report Alarm Events to Computer
*-Change 0-Skip
If alarms have to be reported to a computer.
Yes: Alarms will be reported using the computer telephone number.
No: No alarms will be reported to the computer.
Press 0 to go directly to Computer Telephone Number.
Report access events
No–Report Access Events to Computer
*-Change 0-Skip
If access control events have to be reported to a computer.
Yes: Access control events will be reported using the computer telephone
number.
No: No access control events will be reported to the computer.
Press 0 to go directly to Computer Telephone Number.