Installation guide

142 Advisor Master Programming Guide
Computer telephone number
*-Pause, Ph No:
Cmp:
Holds the telephone number to be dialled by a modem connected to the
ATS1801 printer/computer interface to set up a remote up/download connection.
Up/Download callback number
*-Pause, Ph No:
Cbk:
Holds the telephone number to be called back to set up a remote up/download
connection. Only used for up/download when dialling into the ATS system.
Service telephone number
*-Pause, Ph No:
Srv:
Holds the telephone number to be dialled to set up a connection to a computer.
The service telephone number will be dialled if an user activates the option “Dial
management software”.
Computer address
Computer Address: 0000
Address:
Holds the address to identify the panel to an up/download software package.
Security password
Security Password 0000000000
Pass:
The ATS control panel requires a security password before granting access to
the panel using the upload/download PC software (for example, ATS8100 or
ATS8300). A connection can be made using a telephone line (dial-up) or using
RS232, if the interface is available (ATS1801).
Security passwords are always 10 digits. The default password is 0000000000.
The ATS8100 up/download software can always connect to an ATS control panel
with the default password. However, it updates the password to the password
programmed in the up/download software for the ATS control panel currently
opened.