Installation guide

Advisor Master Programming Guide 151
34-Program system event flags
Event flags are set when specified events occur in the system, such as a mains
failure, a zone generating an alarm or an entry time running.
The system event flags are triggered on system wide events, like mains failures
or DGP’s going offline.
For more information regarding event flags, see Event Flags on page 177.
System event flag settings
Mains fail event flag
Mains Fail No Event Flag
Event Flag:
This event flag is activated when a Mains Failure is detected on the ATS control
panel or a DGP.
Note: Do not use a preset event flag number (1 to 16). Program 0 to disable an
event flag.
Low battery event flag
Low Battery No Event Flag
Event Flag:
This event flag is activated when a low battery is detected on the ATS control
panel or a DGP.
See also Mains fail event flagovenfor.
Fuse fail event flag
Fuse Fail Event Flag
Event Flag:
This event flag is activated when a fuse fail is detected on the ATS control panel
or a DGP.
See also “Mains fail event flagovenfor.
Tamper event Flag
Tamper No Event Flag
Event Flag:
This event flag is activated when a Panel Tamper is detected on the ATS control
panel or a DGP (includes RAS tampers).
See also “Mains fail event flagovenfor.