Installation guide
154 Advisor Master Programming Guide
External siren test event flag
Ext Siren Test No Event Flag
Event Flag:
This flag is active whenever a siren test is active.
All armed pulse event flag
All Armed No Event Flag
Event Flag:
If “NFA2P” option on page 83 is Yes, an event flag/output is provided with or
without event recorder that will be active for 20 seconds, after fully armed
condition is true.
Computer connection active
Computer Connection No Event Flag
Event Flag:
The flag is active whenever a computer connection between the panel and
configuration / management software (Titan or Alliance) is active. The flag is not
to be activated until after the connection has been established.
Line fault
Line Fault No Event Flag
Event Flag:
This event flag is active whenever a line fault condition is active.
Battery test active
Battery test active No Event Flag
Event Flag:
Battery test active event flag is activated when a battery test is being performed
on the Advisor Master Panel or a DGP.
Engineer walk test
Engineer walk test No Event Flag
Event Flag:
This event flag is active whenever an Engineer walk test is active.
Engineer walk test reset
Engineer walk test reset No Event Flag
Event Flag:
This event flag is active for 5 seconds after each walk test (failed, or completed).