Installation guide
Advisor Master Programming Guide 159
How to program
Press one of these keypad buttons to:
• ?, Enter: Enter and display new event flag or zone number. Enter the same
number twice to invert the macro output. It will now trigger the event flag or
output if the result of the equation is not true. An inverted macro output is
recognised by the exclamation mark (!) preceding the number.
• Menu: Select “Event Flag” or “Zone”.
• Enter: Save the displayed details and move to the next display.
Macro inputs
M 1 = E0 Or E0 Or E0 Or E0
*-Chg, Input 1:
Program up to four macro inputs (event flag or output numbers) and whether
each of those inputs performs an AND or an OR function in the logic equation.
When all conditions of the logic equation are met, the macro output is active and
the event flag or zone programmed in the previous step is activated (depending
on any timing function programmed on the macro output).
How to program
Press one of these keypad buttons to:
• ?, Enter: Enter and display new event flag or output number. Enter the same
number twice to invert the macro input. Before calculating the result of the
macro logic equation, the input is inverted. An inverted input is recognised by
the exclamation mark (!) preceding the “E” or “R”.
• Menu: Select “Event Flag” (E) or “Output” (R).
• Enter: Save the displayed details and return to the original macro logic
display.
Macro logic equation
M 1 = E0 Or E0 Or E0 Or E0
*-Chg, Logic 1:
Specify the logical operators that create the macro logic equation. Two operators
are available: AND and OR.
• OR: Result is true if one of the inputs was active.
• AND: Result is true only if both inputs are active.
How to program
Press one of these keypad buttons to:
• Menu: Select “OR” or “AND”.
• Enter: Save the displayed details and return to the original macro logic
display.