Installation guide

Advisor Master Programming Guide 161
42-Reporting class database
Reporting of alarms depends on the settings in Reporting of zone in 1-Zone
databaseon page 7. This setting is a reporting class. There are 8 classes
containing 6 conditions that can be selected for reporting.
Select the reporting class
Class Number
Class No:
Select the class to program. The available classes are:
Class nbr
Name
1
Medical
2
Fire alarms
3
Panic alarms
4
Burglar alarms
5
General alarms
6
24 Hr alarm
7
Fire supervisory
8
System alarms
Each class has multiple types of alarms it can report. e.g The class Panic Alarms
contain SIA reporting for both PA (panic alarm) and HA (hold-up alarm).
For more information on classes or reporting, see 9-Communication optionson
page 94 and Reportingon page 180.
Class settings
Select the class condition
Class 1: Medical - 1. Alarm
Condition No:
Select the condition to program. Select one of the following conditions:
Condition
Reports
1
Alarm
2
Alarm Restore
3
Tamper
4
Tamper Restore
5
Inhibit
6
Inhibit Restore (=uninhibit)