Installation guide
Advisor Master Programming Guide 11
Zone type
Description
24.
Camera 2 Count
Used to increment the film counter for camera 2 by
connecting a normally open contact across the zone. The
counter increments if the zone switches from open to short.
Can only be used with zones on the ATS control panel.
25.
Camera 3 Count
Used to increment the film counter for camera 3 by
connecting a normally open contact across the zone. The
counter increments if the zone switches from open to short.
Can only be used with zones on the ATS control panel.
26.
Camera 4 Count
Used to increment the film counter for camera 4 by
connecting a normally open contact across the zone. The
counter increments if the zone switches from open to short.
Can only be used with zones on the ATS control panel.
27.
Technical with Report
When the zone is activated, opened or shorted, it reports to
the central station. A restore is send when the zone de-
activates
Example: Temperature alarm on freezer
28.
Armed Alarm with Reset
Generates no alarm when the area is disarmed.
Generates an alarm when the area is armed. Resets
automatically when the zone closes to normal state.
Example: Latching glassbreak detector.
29.
24-Hour Alarm with
Reset
Generates an alarm regardless of the status of the area.
Resets automatically when the zone closes to normal state.
Example: Latching glassbreak detector or smoke detector.
30.
Firedoor with Reset
Generates a local alarm when the area is disarmed but does
not report it to the central station.
This alarm can only be acknowledged by entering "user code,
Off, area, Enter" on the arming station. If the zone closes to
normal state, the alarm is reset.
Generates an alarm when the area is armed.
Example: Firedoor or emergency door.
31.
Latching Keyswitch
Used to arm or disarm areas. When the zone switches to:
• Active, the areas arm.
• Normal state, the areas disarm.
This zone type uses an alarm group to perform the
arm/disarm functions.
Example: Latching keyswitch to arm or disarm areas.
You need to program alarm groups (see “5-Alarm groups”,
page 50).
32.
Armed Zone to Event
Flag
Does not perform any action when the area is disarmed.
Activates the zone event flag when the area is armed.
Example: Temperature alarm on freezer activates buzzers.