Advisor Master Programming Guide 173
1, 2
0–All, Area
The user may select all available areas by pressing the “0” key followed by the
Enter key. Pressing Clear will cause the test to be aborted and the user will
return to the installer menu. If aborted at this stage, no event (test started, failed,
etc) will be logged and no test event flag will be set.
Press Enter (without an area number) to start the test.
When the walk test starts, a new walk test event flag will be activated to allow
detectors to be configured to automatically go into walk test and the display
shown below indicates all zones to be tested. If the number of zones to test
exceeds the number that the display can show, then “,.” is displayed at the end of
the list. If so, the user can see all zones to test by viewing name of each zone
individually as is described below.
Untested On 1, 2, 4
0-Cancel, Zone
Each zone that transitions from sealed to unsealed and then back to sealed will
be marked as tested. While the test is running, the displayed list of untested
zones updates automatically without user action so that zones disappear from
the displayed list as they are tested.
While the test is running, the user may enter the number of an untested zone
followed by the Enter key to display that zone’s name as shown below. Here the
user may press Next (down arrow) to scroll through the names untested zones,
or press Enter to return to the numeric list of untested zones shown above.
Untested On 1. PIR In Office
NEXT or ENTER
The test is cancelled if either the “0” or Clear or key is pressed. There is also a
maximum time limit on the test, “Disarm test time” on page 63. The test fails if
this timer expires. In either case, the “Test not completed” display shown below
will be displayed. A message is sent to the central station to indicate test failed,
see events logged table below.
Note: The warning timer functions as normal during this test. That is, a warning
will sound (if warning time programmed) in the normal fashion.
Test not completed
Press ENTER
Otherwise, once all zones have been tested successfully a message “Test
Complete” is displayed, and a message is sent to the central station (see events
logged table below).
Test completed
Press ENTER
If the Clear key is pressed while the test is running, “Please wait” display shown
below is displayed while the aux output is pulsed (described further below).