Installation guide
12 Advisor Master Programming Guide
Zone type
Description
33.
24Hr Alarm & Inhibit
This zone type requires different wiring. The zone can have
the following states:
• Shorted: generates an alarm
• Normal: no alarm
• Active: inhibit (no alarms generated)
• Open: tamper alarm
Example: Designed for shopping centres where only one zone
is available for each shop. A keyswitch is used to inhibit the
zone.
34.
Area Dis/AlmGrp Restr.
Arm
A latching keyswitch that has a special function:
Switching from normal state to active starts the warning time
for the alarm group restriction assigned to the alarm group.
When the warning time expires, the area arms.
Switching from active to normal state disarms the areas.
Example: A keyswitch in a large building with indication that
the area is going to arm.
You need to program alarm groups (see “5-Alarm groups”,
page 50), alarm group restrictions (see “15-Alarm group
restrictions”, page 115), and a warning time (see “6-Timers”,
page 62).
35.
Area AlmGrp Restr Arm
Only
A latching keyswitch that has a special function:
Switching from normal state to active starts the warning time
for the alarm group restriction assigned to the alarm group.
When the warning time expires, the area arms.
Switching from active to normal state does not perform any
action.
Example: a keyswitch in a large building with indication that
the area is going to arm.
You need to program alarm groups (see “5-Alarm groups”,
page 50), alarm group restrictions (see “15-Alarm group
restrictions”, page 115), and a warning time (see “6-Timers”,
page 62).
36.
Camera 5 Count
Used to increment the film counter for camera 5 by
connecting a normally open contact across the zone. The
counter increments if the zone switches from open to short.
Can only be used for zones on the ATS control panel.
37.
Camera 6 Count
Used to increment the film counter for camera 6 by
connecting a normally open contact across the zone. The
counter increments if the zone switches from open to short.
Can only be used for zones on the ATS control panel.
38.
Camera 7 Count
Used to increment the film counter for camera 7 by
connecting a normally open contact across the zone. The
counter increments if the zone switches from open to short.
Can only be used for zones on the ATS control panel.
39.
Camera 8 Count
Used to increment the film counter for camera 8 by
connecting a normally open contact across the zone. The
counter increments if the zone switches from open to short.
Can only be used for zones on the ATS control panel.