Installation guide
174 Advisor Master Programming Guide
When the aux output pulsing is completed, the walk test will be exited
automatically to the install menu.
Test not completed
Please wait
At the end of the walk test, the walk test event flag will be deactivated.
The test will cause the following events to be logged. These events are sent as
messages to the central monitoring station:
Event logged
When logged
ACCESS_TEST_STARTED
When test started
WALK_TEST_ZONE_TESTED
When a zone is tested and Titan or Alliance is connected
to the panel (computer connection active event flag set).
Event message includes the zone number of the tested
zone.
This event is not sent to central stations.
WALK_TEST_ZONE_NOT_TESTED
When a zone fails the test and Titan or Alliance is
connected to the panel (computer connection active event
flag set). Event message includes the zone number of the
tested zone.
This event is not sent to central stations.
ACCESS_TEST_FAILED
If user cancels the test or on test timeout (failed)
ACCESS_TEST_COMPLETED
Test completed successfully
Note: If Titan or Alliance is connected to the panel (computer connection active
event flag set), the “WALK_TEST_ZONE_TESTED”,
“WALK_TEST_ZONE_NOT_TESTED”, “ACCESS_TEST_FAILED” or
“ACCESS_TEST_COMPLETED” will be logged in the panel and send to Titan
history.
If Titan or Alliance is not connected to the panel (computer connection active
event flag not set), the “WALK_TEST_ZONE_TESTED” and
“WALK_TEST_ZONE_NOT_TESTED” will be Ignored and not logged.Only the
“ACCESS_TEST_FAILED” or “ACCESS_TEST_COMPLETED” will be logged in
the panel.
This is to prevent the panel memory from being filled with events when Titan is
not connected.
After each walk test (failed, or completed) an “Engineer Walk Test Reset” system
event flag will be activated for 5 seconds. Users may use this event flag to switch
the aux output (output 251) to reset any latched detectors in alarm.
If the user presses the Enter key to exit the test menu while the aux output is
deactivated, a closing message will be displayed as shown below. The test will
then automatically exit from the engineer walk test when the aux output is
restored.