Installation guide
178 Advisor Master Programming Guide
Which event flags are predefined?
There are 16 predefined event flags. These are:
Event
Name
Description
1
External Siren
Default External siren event flag (assigned in area database).
If set to Yes in the zone database, activates when any External siren
activates in any area.
2
Armed Alarm
If set to Yes on the zone database, activates when an alarm is
generated by the zone and all the areas assigned to the zone are
armed. It is used to activate the system strobe.
3
Armed Alarm
As event flag 2
4
Armed Alarm
As event flag 2
5
Armed Alarm
As event flag 2
6
Disarmed Alarm
If set to Yes in the zone database, activates when an alarm is
generated by the zone and one or more of the areas assigned to the
zone are disarmed.
7
Disarmed Alarm
As event flag 6
8
24 Hour Alarm
If set to Yes in the zone database, activates at any time an alarm is
generated by the zone.
9
Armed Alarm
As event flag 2
10
Armed Alarm
As event flag 2
11
Armed Alarm
As event flag 2
12
Armed Alarm
As event flag 2
13
Internal Siren
Default event flag for internal siren (assigned in area database).
If set to Yes in the zone database, activates when any Internal siren
activates in any area.
16
Testing
Activates during the arm test. A testing event is used to activate a
device that allows the testing of other devices that need to be tested.
For example activate a light to test a light detector.
The tester event flag activates for half the “Testing event flag time” on
page 65 programmed in programming menu “6-Timers”. The
remaining period of the arm test time is settling time to allow the
tested device to switch back to normal state.
I.e. Make sure that the arm test time is longer than the testing event
time.
More about event flags?
For the usage of event flags, see the sections concerning:
• Menu “1-Zone database” on page 7.
• Menu “2-Area database” on page 28.
• Menu “3-RAS database” on page 39.
• Menu “16-Event to output” on page 121.
• Menu “21-Zone shunts” on page 130.