Installation guide
Advisor Master Programming Guide 13
Zone type
Description
40.
Dis. Susp. Delay/Arm
Alm
If the area is disarmed it has the following functions:
• Shorted: Activates cameras in the areas that are assigned
to the zone. When the zone switches back to normal, the
cameras continue to operate for the suspicion time.
• Normal: No alarm.
• Active: Generates an alarm but does not report to the
central station until the delayed alarm timer has expired or
a second delayed alarm is activated.
• Open: Tamper
Generates a general burglar alarm when the area is armed.
Note: You need to program the Delayed Alarm Time. See “6-
Timers” on page 62 for more information.
41.
Entry/Exit Firedoor
Generates a local alarm when the area is disarmed.
Automatically activates an audible alert on arming stations
assigned to the same areas (regardless of the event flag
programming). The only event flag activated is the zone event
flag.
This local alarm can be reset by entering "Enter, Enter, 0,
Enter" or "user code, Off, area, Enter" on the arming station to
stop the audible alert and cancel the event.
If the zone remains activated, it generates a new local alarm
after the programmed local alarm reminder time.
When the area is armed, the exit timer starts and activating
the zone will generate no alarm. If the zone is activated and
the exit time has expired, the entry timer starts. When the exit
time has expired, an alarm will be generated.
Example: A firedoor that is also used to enter the premises.
Note: You need to program the entry/exit timer (see “2-Area
database”, page 28), and the local alarm reminder time (see
“6-Timers”, page 62).
42.
Entry/Exit Firedoor w
Code
Generates a local alarm when the area is disarmed but does
not report it to the central station.
This alarm can only be acknowledged by entering "user code,
Off, area, Enter" on the arming station.
When the area is armed, the exit timer starts and activating
the zone will generate no alarm. If the zone is activated and
the exit time has expired, the entry timer starts. When the exit
time has expired, an alarm will be generated.
Example: A firedoor that is also used to enter the premises.
Note: You need to program the entry/exit timer. See “2-Area
database” on page 28 for more information.
43.
Disarm Zone to Event
Flag
Activates the zone event when the area is disarmed.
Does not perform any action when the area is armed.
Example: Opening a closet activates a buzzer.