Installation guide
Advisor Master Programming Guide 189
Description
Contact ID
SIA
Event
Area
Pt/User
Event
Pt/User
Area Out of Timezone
E608
00
C 012
OK
000
Area Within Timezone
R608
00
C 012
–
–
Film Out
E150
00
C 011
–
–
Film Out Restore
R150
00
C 011
–
–
Emergency Alarm
E102
00
C 009
QA
000
Auto Test Call
E602
00
C 016
RP
000
Service Requested
E411
00
C 013
YX
000
Line Fault Monitor Fail
E351
00
C 014
LT
connection
type [1]
Line Fault Monitor Restored
R351
00
C 014
LR
connection
type [1]
Direct Connect via J15 Port
E416
00
C 010
–
–
Program Mode Entered
E150
00
C 015
LB
000
Program Mode Exited
R150
00
C 015
LS
000
Fire long supervision fault
BZ [D]
TA [A]
001–256
Fire long supervision restore
BJ [D]
TR [A]
001–256
Sensor battery low
XT
001–256
Sensor battery restore
XR
001–256
Fire detector “Clean Me” signal
AS
001–256
Fire detector “Clean Me” restore
AN
001–256
RF DGP jamming fault
XQ [D]
TA [A]
000
RF DGP jamming restore
XH [D]
TR [A]
000
Anti-Mask
BT
001–256
Anti-Mask Restore
BR
001–256
Zone Fault
BT
001–256
Zone Fault Restore
BR
001–256
Battery Fail
YT
301–316
Battery Restore
YR
301–316
PSU Fail
YT
301–316
PSU Restore
YR
301–316
Area Armed Automatically
E403
01–16
000
CP
000
Area Disarmed Automatically
R403
01–16
000
OA
000
[D] Disarmed state
[A] Armed state
[1] Connection type is described in “Connection type” on page 100.