Installation guide
Advisor Master Programming Guide 195
Data gathering panels - models ATS120X(E)(N),
ATS121X(L)(E), ATS1220
Condition
Possible cause
The "Tx" LED on the data
gathering panel is not flashing.
The dipswitches may be incorrectly set (the address recorded
on the DGP may be incorrect and therefore polling to the DGP
is not being acknowledged).
The system databus cable may be connected incorrectly.
The data gathering panel is not programmed to be polled.
"Tx" and "Rx" LED’s are not
operating.
No power or low power.
The system databus cable may be connected incorrectly or the
power supply is faulty (mains or battery).
The data gathering panel
appears to be going off-line and
on-line (indicated by "DGP Fail"
on a LCD arming station).
The termination may be incorrect. See Advisor Master
Installation Guide, “Cabling”.
Some or all DGP zones are
permanently in tamper (or
permanently in alarm if "Dual
zone” on page 73 is set to No).
The zone numbers for the DGP have been calculated
incorrectly, and zone type numbers have therefore been
assigned to the wrong zones in the zone database. See the
installation guide on “zones and outputs allocated to each
DGP”.
The EOL resistors are wrong or the wrong resistor value is
programmed in “7-System options” (page 70).
There is a problem with wiring the zones. To check the voltage
or resistor values, see Advisor Master Installation Guide.
The ATS1202 expansion module(s) (if fitted) have the
dipswitches incorrectly set.
Expansion module: 1st 2nd 3rd
Dipswitch 1 ON OFF OFF
Dipswitch 2 OFF ON OFF
Dipswitch 3 OFF OFF ON
Dipswitch 4 not used
Two or three ATS1202
expansion modules are fitted to
increase the DGP to 24 or 32
zones, but the 17th to 32nd
zones on the DGP do not seem
to function.
Dipswitch A on the DGP has not been set to ON (ATS1201), or
the polling for the DGP address +1 is not set properly
(ATS1201E, ATS1203(E), ATS1204(E)(N) or ATS121x(L)E).
Four-way relay module(s)
(ATS1810) being used with the
DGP do not function, but some
of the LED’s on the module
appear to be permanently on.
Dipswitch B on the DGP is set to ON (dipswitch B should only
be ON if 8-way relay (ATS1811) modules or 16 open collector
modules (ATS1820/1821) are being used) (ATS1201,
ATS1210, ATS1220).
For ATS1201E, ATS1203(E), ATS1204(E)(N), ATS121X(L)E
the DGP Settings > Static outputs option in the DGP
programming menu is set to Clocked outputs.
8-way relay modules
(ATS1811) or 16-way open
collector modules (ATS1820)
connected to the DGP do not
function.
Dipswitch B on the DGP has not been set to ON (ATS1201,
ATS1210, ATS1220).
For ATS1201E, ATS1203(E), ATS1204(E)(N), ATS121X(L)E
the DGP Settings > Static outputs option in the DGP
programming menu is not set to Clocked outputs.