Options required by EN 50131 compliance
The following options and values are mandatory for EN 50131-1 Grade 3
regulations.
Entry timeon page 29: ≤ 45 s
Reset from RAS without codeon page 43: No
Timed lockout by wrong codeson page 44: Yes
Timed lockout by wrong badgeson page 47: Yes
External siren set toon page 65: 90 s to 15 min
Internal siren set toon page 65: 90 s to 15 min
Siren delay set toon page 66: ≤ 10 min
Mains fail delay timeon page 66: 60 s
Delay reporting alarms foron page 66: ≤ 10 s
Screen saver timeout timeon page 66: ≤ 60 s
RAS card & PIN timeouton page 67: 30 s
Abort time (sec)on page 68: 30 s
RAS lockout timeon page 68: ≥ 90 s
Areas selected for total disarmon page 70: 0
Test modeon page 71: 0, No test
Dual zoneon page 73: Yes
Auto uninhibit on disarmon page 73: Yes
System alarms set siren and strobeon page 74: Yes
Latching system alarmson page 74: Yes
Disable code from displayingon page 76: Yes
Sirens only after FTCon page 77: No
Inhibit zone tamperon page 78: Yes
Report multiple alarmson page 79: Yes
Report multiple restoreson page 79: No
Ignore battery fault when armingon page 80: No
User can do engineering reseton page 80: No
Engineer entry protecton page 80: No
Send arming after exiton page 80: Yes
End of line resistor codeon page 81: 1, 4k7
Use minimum 6 digits PIN codes
Siren Typeon page 81: 1, Constant DC Voltage
Inhibit alarm report on exit faulton page 82: Yes
Disable tamper report in disarmon page 82: No
Inhibit ext.sir&strobe for disarm tamperon page 82: Yes
ATS system codeon page 82: 00000
ACPOon page 83: No
EE confirm disable (ACPO)on page 83: No
Engineer reset on ACPO zone B alarmon page 83: No
NFA2Pon page 83: No
Installer dual codeon page 84: Yes
Enable buzzer on mains/line faulton page 84: No
Screen saveron page 85: Yes
Enable log limitationson page 85: Yes
Confirm areaon page 85: None