Installation guide
Advisor Master Programming Guide 199
• “Indicate inhibited zones” on page 85: Yes
• “Eng Rst on ACPO zone B tamper” on page 85: No
• “Eng Rst on ACPO system B tamper” on page 86: No
• “Security grade” on page 86: 3 (Med to High Risk)
• “Ignore AC mains fault when arming” on page 86: No
• “Latch mains/battery/line faults” on page 86: Yes
• “Enable PA siren on FTC” on page 87: No
• “Latch AWDGP jam and supervision” on page 87: No
• “Prevent arming on faults” on page 88: Yes
• “Authorize computer connection” on page 144: Yes
• “Battery test frequency” on page 147: Every day
• “56-Siren calibration” on page 176: values are calculated
Note: The options above can be set automatically by applying Grade 3 defaults.
See “14-Defaults” on page 113 for more information. Sirens must be calibrated
separately. See “Siren calibration” on page 6 for more details.
The following features are not allowed (not evaluated):
• Keyswitch zone types to set and unset the system. See “Zone type” en page
7.
• Presetting indication and any automatic override of set prevention.
Refer to Table 17 below for all supported options for notification requirements.
Table 17: EN 50131-1 2006 options
Notification equipment (Alarm
reporting)
Grade 3 options
A
B
C
D
Remotely powered audible WD
2
Optional
Optional
Optional
Self-powered audible WD
Optional
1
Optional
Optional
Main ATS
ATS 4
ATS 4
ATS 4
ATS 5
Additional ATS
Optional
Optional
ATS 3
Optional
The key variations of cards and keys are the following:
Both
• ATS1471 (1 pc.) and ATS1477 (10 pcs.) tags as well as
• ATS1475 (10 pcs.) card badges
have a number of key variations of 67 million minimum.
Both make use of 26 bit (to 48 bit) Hitag protocol.