Zone type
Description
57.
Technical Report &
Screen
When the zone is activated or tampered, it reports to the
central station and puts the zone event text on the display. A
restore is sent when the zone switches to normal state.
Example: Temperature alarm on freezer
Note: You need to program the zone event text. See “7-
System options” on page 70.
58.
Technical Screen
When the zone is activated, opened or shorted, it puts the
zone event text on the display.
Example: Temperature alarm on freezer
Note: You need to program the zone event text. See “7-
System options” on page 70.
59.
24 Hour Alarm If No
TZ 41
If timezone 41 is invalid, the zone has the following function:
Generates an alarm regardless of the status of the area.
If timezone 41 is valid, the zone is disabled.
Note: You need to program the local alarm reminder time
(see “6-Timers”, page 62) and to link timezone 41 to an output
(see “16-Event to output”, page 121).
60.
Exit Terminator
This zone type is used to terminate an exit time. If the zone
switches from active to normal, the exit time will be terminated
and the areas are completely armed.
61.
Do not use
62.
Do not use
63.
Do not use
64.
Do not use
65.
Engineering reset switch
This zone type allows you to perform an engineer reset via an
input.
Note: You need to program the correct area to perform the
reset.
66.
Final door set
This zone type is used to shorten the exit timer when the
sensor associated with this input is activated, normally on an
exit door. When activated, it shortens the exit timer to 4
seconds.(If ~ is needed, set the Exit Time to 0)
67.
Latched detector
This zone type has a 24 hour alarm that can be isolated and
associated with a latched detector event flag (see “Latched
reset event flag” on page 32).It is normally used for latched
fire detectors.
68.
Antimask detector
Generates no alarm when the area is disarmed.
Gives a special indication for remote diagnostic purposes.
Example: Antimask detector.
During remote diagnostics, this zone if armed will be indicated
as an antimask alarm.
69.
Alarm (ACPO) zone
Generates no alarm when the area is disarmed
Generates an alarm when the area is armed. It is inhibited
during the entry exit timed periods.
The zone must be closed when arming the area.