Installation guide
Advisor Master Programming Guide 21
There are five test procedure options, each identified by a reference number.
This reference number is used to program a testing procedure. See Table 4
below for a description of each test type.
Notes
• This record is invalid unless the test mode is correctly programmed in the “7-
System options” (see page 70).
• During the arm test, the testing event flag (event flag 16) will be activated
during half the “Testing event flag” time (see “6-Timers”, page 62). Use this
event flag to activate devices to generate alarms, for example when using
vault sensors. The other half is used for the device to switch back to normal
state.
Table 4: List of test type options
Reference
number
Test type name
Description
0.
No Testing
Required
Program a zone with test type zero to exclude it from both the
disarm test and the arm test. It also does not appear in any
test report. The zone is not disabled during the disarm test.
Example: A duress button that is active during test mode,
siren cover, and panel tamper.
1.
Test During
Disarm Test
Program a zone with test type 1 to include it in the disarm
test. The zone is disabled during any disarm test on areas
assigned to it.
Example: Hold-up button
2.
Tested In Arm
Test & Disarmed
Program a zone with test type 2 to include it in the arm test. If
the zone is activated during disarmed mode, it is considered
tested and is not be re-tested when the arm test is carried out.
Example: PIR’s, doors.
3.
Test During Arm
Test
Program a zone with test type 3 to include in the arm test.
Example: Any device that needs to be automatically tested.
4.
Set E/Flag 13
During Disarm
Test:
Program a zone with test type 4 to event flag 13 during the
disarm test.
This test type is used for testing devices activated by
disarmed alarm zone types (e.g.: Hold-up buttons). The
device must already be programmed to be activated by
disarmed alarm event flag 13.
5.
Set Pre-Alarm
During Disarm
Test
Program a zone with test type 5 to activate the pre-alarm
event flag during the disarm test in the area(s) assigned to the
zone.
This test type is used to test devices that are activated during
the delayed hold-up time (e.g.: a discreetly placed LED that
indicates to the user that the hold-up button is active).
The pre-alarm event flag number is programmed in “2-Area
database” on page 28.
6.
Frequently used
detector
Program a zone with test type 6 during a Remote Diagnostic
session to determine which zone has not been triggered
during the last 6 hours after the last arming.