Note: For the Internal siren event flag to operate, you must also program the
Internal siren event flag number in the area database for each of the areas that
activate internal sirens and that are assigned to the zone. Refer to “2-Area
database” on page 28. See also “Zone event flag” on page 22.
External siren event flag
YES-External Siren, Program in DB
*-Change 0-Skip
Select if the external siren event flag should be activated. The External siren
event flag is assigned in the Area database.
Yes: The External siren event flag specified in the area database is activated
when the zone generates an alarm, and all the areas assigned to the zone are
armed.
No: The External siren event flag will not be triggered by an alarm in this zone.
Note: For the External siren event flag to operate, you must also program the
External siren event flag number in the area database for each of the areas that
activate internal sirens and that are assigned to the zone. Refer to “2-Area
database” on page 28.
Keypad buzzer
NO-Keypad Buzzer
*-Change 0-Skip
The keypad buzzer can be activated during an alarm.
Yes: When the zone generates an alarm, the keypad buzzer is activated on the
keypads that control the areas assigned to the zone.
No: An alarm on the zone will not trigger the buzzer.
See also “Zone event flag” on page 22.
Make all events 24 hour
NO-Make All Events 24 Hour
*-Change 0-Skip
Used to activate all event flags on alarm.
Yes: All armed and disarmed alarm event flags are triggered when the zone
generates an alarm, regardless if the status of the area.
No: The armed and disarmed alarm flags are triggered depending on the status
of the area(s) assigned to the zone
See also “Zone event flag” on page 22.