Installation guide
Advisor Master Programming Guide 25
Trigger EF 11, armed alarm
See “Trigger EF 2, armed alarm” on page 24.
Trigger zone EF if active
NO-Trigger Zone Event Flag if Active
*-Change 0-Skip
Yes: The zone event flag is triggered when the zone is active, regardless of the
status of the area(s) assigned to the zone.
No: The zone event flag is only triggered when the zone generates an alarm.
See also “Zone event flag” (page 22).
Trigger chime/camera EF in area DB
No–Chime/Camera Event, Program in Area DB
*-Change 0-Skip
Yes: The chime/camera event flag programmed in the area database is activated
whenever the zone generates an alarm and the area is disarmed.
No: Chime/camera event flag will not be triggered.
Note: If the chime/camera event flag is to operate, you must also program the
chime/camera event flag number in the area database for each of the areas that
have cameras and that are assigned to the zone. Refer to “Chime/camera event
flag” on page 31.
To activate the camera event flag when the area is armed, set “Make all events
24 hour” on page 23 to Yes.
If enabled in System Options > “Enable chime” on page 87, the event flag will
become and react as a Zone Chime event flag. During the areas disarmed period
the chime event flag is set each time a zone, enabled for chime, changes from
normal (4K7) to active (9K4). The flag will remain set for the time (1 to 255
seconds) programmed in Timers > “Chime time is set to” on page 68.
The chime function works with the following zone types:
• 2: Armed Alarm
• 13: Entry Exit no arm check
• 14: Access no arm check
• 28: Armed alarm with auto-reset
• 60: Exit terminator
• 66: Final door set
• 68: Anti-mask detector
Notes
• To activate the camera event flag when the area is armed, set Make all
events 24 hour to YES.
• When set to YES, the Siren Event flag will be ignored to have silent alarms
(Panic or Hold-up alarm).