Installation guide

Advisor Master Programming Guide 25
Trigger EF 11, armed alarm
See “Trigger EF 2, armed alarmon page 24.
Trigger zone EF if active
NO-Trigger Zone Event Flag if Active
*-Change 0-Skip
Yes: The zone event flag is triggered when the zone is active, regardless of the
status of the area(s) assigned to the zone.
No: The zone event flag is only triggered when the zone generates an alarm.
See also Zone event flag (page 22).
Trigger chime/camera EF in area DB
NoChime/Camera Event, Program in Area DB
*-Change 0-Skip
Yes: The chime/camera event flag programmed in the area database is activated
whenever the zone generates an alarm and the area is disarmed.
No: Chime/camera event flag will not be triggered.
Note: If the chime/camera event flag is to operate, you must also program the
chime/camera event flag number in the area database for each of the areas that
have cameras and that are assigned to the zone. Refer to Chime/camera event
flagon page 31.
To activate the camera event flag when the area is armed, set Make all events
24 houron page 23 to Yes.
If enabled in System Options > “Enable chimeon page 87, the event flag will
become and react as a Zone Chime event flag. During the areas disarmed period
the chime event flag is set each time a zone, enabled for chime, changes from
normal (4K7) to active (9K4). The flag will remain set for the time (1 to 255
seconds) programmed in Timers > “Chime time is set toon page 68.
The chime function works with the following zone types:
2: Armed Alarm
13: Entry Exit no arm check
14: Access no arm check
28: Armed alarm with auto-reset
60: Exit terminator
66: Final door set
68: Anti-mask detector
Notes
To activate the camera event flag when the area is armed, set Make all
events 24 hour to YES.
When set to YES, the Siren Event flag will be ignored to have silent alarms
(Panic or Hold-up alarm).