Installation guide

26 Advisor Master Programming Guide
See also Zone event flag (page 22).
Print zone when active
NO-Print Zone When Active
*-Change 0-Skip
Yes: Activation of the zone has to be printed or sent to a computer.
No: Activation does not have to be printed or sent to a computer.
How to program
See How to program” on page 5 for information on which keys to use.
Engineer walk test
YES-Engineer Walk Test
*-Change 0-Skip
Yes: Zone will be configured to be included in the engineer walk test.
No: Zone will not be configured to be included in the engineer walk test.
Note: Default will be Yes.
Double Knock
NO-Double Knock
*-Change 0-Skip
Yes: This zone will be configured for double knock activation in a certain time
interval
No: Zone will not be configured for double knock functionality
If set to Yes and a zone becomes active, at the point where the alarm condition
will normally be activated, two zone timers shall be triggered. An interval timer is
preset with the value contained in Double knock interval (min)on page 67, and
begins counting downwards. A second timer (duration) is preset with the value
contained in Double knock duration (sec)on page 67, and also counts
downwards.
Notes
Only the following zone types are applicable:
- 1: disarmed alarm
- 2: armed alarm
- 4: access alarm
- 14: access alarm (no arm check)
Default is No.