Installation guide

28 Advisor Master Programming Guide
2-Area database
Each area can be programmed with a number of options, like the area name,
entry- and exit times, event flags etc. Before going any further, select the area to
program.
Select the area to program
Area Database
Area No:
Enter the area number to program.
Area settings
Area name
Area Name: 0260, Workshop
Text No:
Every area can be programmed with a name to identify the area.
The words are selected from a list already held by the ATS system. They can be
either from the list of standard words available (see Table 9 on page 104), or
from a list of words that you have programmed yourself (see 10-Program text
on page 102).
The display shows the current area name, preceded by its reference number.
How to program a name
Names are programmed using the reference number that identifies a word. Once
the reference number is entered, the name is visible behind the number.
Exit time
Area 1 : > Exit Time 60 Entry Time 30
Exit time:
Every area has its own exit timers. Exit timers allow users that arm an area, to
leave the premises without generating an alarm (using access or entry/exit
zones). Only after the exit timers have expired, an alarm can occur.
Each area can be programmed with one exit time. The exit times apply to zone
types 3, 4, 13, 14, 41, and 42 (all entry/exit or access). The entry time however
can only be started with zone types 3, 13, 41, and 42 (entry/exit).
The exit timers can be programmed from 0 to 255 seconds.
Note: If zones are assigned to more then one area, the longest exit time is used.
See 1-Zone database on page 7.