Installation guide

Advisor Master Programming Guide 29
Entry time
Area 1 : > Exit Time 60 Entry Time 30
Entry time:
Every area has its own entry timers. When entering the premises via a entry/exit
zone, the entry time starts. A user can disarm the area while the entry time is
running without generating an alarm.
Each area can be programmed with one entry time. The entry times apply to
zone types 3, 4, 13, 14, 41, and 42 (all entry/exit or access). The entry time
however can only be started with zone types 3, 13, 41, and 42 (entry/exit).
The entry timers can be programmed from 0 to 255 seconds.
Note: If zones are assigned to more then one area, the longest entry and exit
time is used. See 1-Zone database on page 7.
External siren event flag
Area 1 External Siren No Event Flag
Event Flag:
Areas are capable of triggering event flags. Different from event flags in the zone
database, these event flags are triggered by an area event, not from a particular
zone event.
The External siren event flag is triggered if any zone with the External Siren
Event flag set to Yes generates an alarm. Each area can have its own external
siren, using different event flags for each area. See Event Flagson page 177.
Note: The default value for this option is 1.
Internal siren event flag
Area 1 Internal Siren No Event Flag
Event Flag:
The Internal siren event flag is triggered if any zone with the Internal Siren Event
flag set to Yes generates an alarm. Each area can have its own internal siren,
using different event flags for each area. See Event Flagson page 177.
Note: The default value for this option is 13.
Area disarmed event flag
Area 1 Disarmed No Event Flag
Event Flag:
Active when the area is disarmed.
See also External siren event flag above.