Installation guide
30 Advisor Master Programming Guide
Area active event flag
Area 1 Active No Event Flag
Event Flag:
Used to indicate if any zone in the area is active, excluding zones that can be
used to change the status of an area, that are used for camera’s or that are of
zone type Unused.
See also “External siren event flag” on page 29.
Inhibited event flag
Area 1 Inhibited No Event Flag
Event Flag:
A zone in this area has been inhibited.
See also “External siren event flag” on page 29.
Armed Alarm event flag
Area 1 Armed Alarm No Event Flag
Event Flag:
Activates on an alarm when the area is armed.
See also “External siren event flag” on page 29.
Disarmed alarm event flag
Area 1 Disarmed Alarm No Event Flag
Event Flag:
Activates on an alarm when the area is disarmed.
See also “External siren event flag” on page 29.
Local alarm event flag
Area 1 Local Alarm No Event Flag
Event Flag:
Activates on local alarms from firedoor and 24 hr local fail zone types in the area.
See also “External siren event flag” on page 29.
Activates on zone types 15, 16, 18, 21, 30, 41, 42, 44 and 56. See “1-Zone
database”, Table 3 (page 8) for more information.
Exit timer event flag
Area 1 Exit Timer No Event Flag
Event Flag:
Activates when the exit time for the area is running.
See also “External siren event flag” on page 29.