Installation guide
Advisor Master Programming Guide 33
Area disarmed time
Area Disarmed Time: 0 Mins
Enter Mins:
When using alarm group restrictions, one of the options available is to disarm an
area for a disarmed period. If the Area Disarmed time is not ‘0’, then this time will
be used. See 15-Alarm group restrictions on page 115.
Note: If the Disarmed time for the Alarm group Restriction is set to 0, to specify
that the area will not re-arm, the "Area Disarmed Time" does apply for that area
(see 6-Timers on page 62 for more information).
Report to Central Station 1
YES-Report To CS1
*-Change 0-Skip
Yes: Report opening/closing and Late to Close to Central Station 1.
No: Do not report to Central Station 1.
Report to Central Station 2
See “Report to Central Station 1”.
Report to Central Station 3
See “Report to Central Station 1”.
Report to Central Station 4
See “Report to Central Station 1”.
Enable audio listen in
NO-Enable Audio Listen In
*-Change 0-Skip
When audio listen in has to be enabled for this area, use this option.
Yes: Audio Listen in enabled for this area.
No: Audio Listen in disabled.
Enable exit fault reporting
NO-Enable Exit Faults
*-Change 0-Skip
Exit faults occur when an access zone or exit zone is still open at the moment the
exit time expires. On an exit fault a local alarm is generated and a special Exit
Fault is reported to the central station.
Yes: Enable exit fault reporting.
No: No exit fault reporting.