34 Advisor Master Programming Guide
A&B alarm reporting (ACPO)
NO-A&B Alarm Reporting (ACPO)
*-Change 0-Skip
Special facility for ACPO to be able to transmit verfied alarms.
When the first zone activates, an alarm will be transmitted to the central station. If
a second zone activates within the A to B time, a verified alarm will be
transmitted. Otherwise a normal alarm will be transmitted.
Yes: Use verified A&B reporting.
No: No A&B alarm reporting.
See “A to B alarm delay (ACPO)” (page 66).
Disable arming if all inhibited
NO-Disable Arming If All Inhibited
*-Change 0-Skip
When arming an area should not be possible if all zones within the area are
inhibited, set this menu to Yes.
Yes: No arming available if all zones in the area are inhibited.
No: Arming is available when all zones in the area are inhibited.
KeyBox time (min)
KeyBox Time: 5 Mins
Enter Mins:
Extends the exit time. Immediately after the exit timer expires, the KeyBox timer
starts for a duration of N minutes. Close the zone before this additional KeyBox
timer expires. If it is not closed, a full alarm will be triggered again even if the
previous trigger was also an alarm. During exit timer + KeyBox timer, openings
and closings will not be registered and will not cause an alarm.
Area tamper alarm event flag
Tamper Alarm No Event Flag
Event Flag:
This event flag becomes active whenever a tamper alarm is detected on an input
associated with the specific area, and is independent of arming state.
Arm complete event flag
Arm Complete No Event Flag
Event Flag:
Arm complete event flag indicates completion of arming.