Installation guide

Advisor Master Programming Guide 35
Disarm complete event flag
Disarm Complete No Event Flag
Event Flag:
Disarm complete event flag indicates completion of disarming.
Alert indicator event flag
Alert Indicator No Event Flag
Event Flag:
When an event occurs requiring text to be displayed on the user interface during
the disarmed state, the alert indicator activates.
Panic alarm event flag
Panic Alarm No Event Flag
Event Flag:
An event flag corresponding to the state of the PA Area Alarm Timer running
state (one per area).
Anti-mask/fault event flag
Anti-Mask/Fault No Event Flag
Event Flag:
Activates when a detector is masked or on a detector fault.
Note: Detector combined anit-mask/fault state refers to the lower alarm window
(nominally 2,35 kΩ) if corresponding zone has the Anti-mask detector option
enabled. See “Anti-mask detectoron page 27 for more details.
Mask event flag
Mask Event Flag
Event Flag:
Activates when a detector is masked.
Notes
Detector masked state nominally 14,7 kΩ (4,7 kΩ EOL resistor only).
Activates if corresponding zone has the Anti-Mask detector option enabled.
See Anti-mask detectoron page 27 for more details.
Fault event flag
Fault No Event Flag
Event Flag:
Activates when a detector is faulty.
Notes
Detector fault state nominally 19,4 kΩ (4,7 kΩ EOL resistor only).