• Activates if corresponding zone has the Anti-Mask detector option enabled.
See “Anti-mask detector” on page 27 for more details.
Panic Alarm (Hold-up) A
Panic Alarm (Hold-up) A No Event Flag
Event Flag:
This event flag is activated when the area identifies a first panic alarm.
Panic Alarm (Hold-up) B
Panic Alarm (Hold-up) A No Event Flag
Event Flag:
This event flag is activated when the area identifies a confirmed panic alarm.
Part set exit time
NO-Part Set Exit Time
*-Change 0-Skip
If set to Yes, Part Set arming uses the programmed exit time. If an exit terminator
(zone type 60) is programmed for the area and the Full Set exit time is zero, the
exit time is 20 seconds.
Part set entry time
YES-Part Set Entry Time
*-Change 0-Skip
Yes: Normal entry procedure when Part Set armed.
No: No entry time for Part Set arming.
Notes
• If set to No, Part Set armed, and an entry exit zone is activated, an instant
alarm condition will occur.
• If an entry exit zone (types 3 or 13) has multiple areas assign to the zone, and
one or more of the areas are Part Set armed, setting this menu to No for any
one area will exclude the entry time for the assigned areas.
Part set exit buzzer
NO-Part Set Exit Buzzer
*-Change 0-Skip
Yes: Buzzer will sound for the Part Set arming exit time.
No: Buzzer will not sound for the Part Set arming exit time.
Note: If the set to NO, although there is no exit buzzer, the exit time is still
retained.